We sell a variety of analog sensors that do not have their own API, they simply output a voltage that can be converted to a digital value using a specific formula. By matching the VoltageInputSensorType to your analog sensor, the correct formula will automatically be applied to data when you get the VoltageInputSensorValue or subscribe to the VoltageInput_SensorChange event.
VoltageInput_SensorChange event has its own change trigger associated with it: VoltageInputSensorValueChangeTrigger.VoltageInputSensorValue or subscribing to the VoltageInput_SensorChange event will have a VoltageInputSensorUnit associated with it.PhidgetDeviceSerialNumber or PhidgetChannel, VoltageInputSensorType is set after the device is opened, not before.

|
|
Device In Device # Identification |
|
|
error in (no error) error in can accept error information wired from VIs previously called. |
|
|
status status is TRUE (X) if an error occurred or FALSE (checkmark) to indicate a warning or that no error occurred. Right-click the error in control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error. |
|
|
code code is the error or warning code. Right-click the error in control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error. |
|
|
source source describes the origin of the error or warning. Right-click the error in control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error. |
|
|
Sensor Type The sensor type value
1010_0 (ver: 903, 904) Voltage Input: Default: SENSOR_TYPE_VOLTAGE
1011_0 (ver: 100, 101, 102, 103) Voltage Input: Default: SENSOR_TYPE_VOLTAGE
1013_0 (ver: 800, 811, 820) Voltage Input: Default: SENSOR_TYPE_VOLTAGE
1013_0 (ver: 821, 823) Voltage Input: Default: SENSOR_TYPE_VOLTAGE
1018_0 (ver: 824, 825, 826) Voltage Input: Default: SENSOR_TYPE_VOLTAGE
1018_1 (ver: 826) Voltage Input: Default: SENSOR_TYPE_VOLTAGE
1018_2 (ver: 900, 901, 902, 903, 904) Voltage Input: Default: SENSOR_TYPE_VOLTAGE
1018_3 (ver: 1000, 1001) Voltage Input: Default: SENSOR_TYPE_VOLTAGE
1019_0 (ver: 826) Voltage Input: Default: SENSOR_TYPE_VOLTAGE
1019_1 (ver: 903, 904) Voltage Input: Default: SENSOR_TYPE_VOLTAGE
1065_0 (ver: 100, 101) Voltage Input: Default: SENSOR_TYPE_VOLTAGE
1065_1 (ver: 100, 101) Voltage Input: Default: SENSOR_TYPE_VOLTAGE
1070_0 (ver: 826) Voltage Input: Default: SENSOR_TYPE_VOLTAGE
1072_0 (ver: 903) Voltage Input: Default: SENSOR_TYPE_VOLTAGE
1073_0 (ver: 904) Voltage Input: Default: SENSOR_TYPE_VOLTAGE
1202_0 (ver: 100) Voltage Input: Default: SENSOR_TYPE_VOLTAGE
1202_0 (ver: 120, 121) Voltage Input: Default: SENSOR_TYPE_VOLTAGE
1202_1 (ver: 123, 124) Voltage Input: Default: SENSOR_TYPE_VOLTAGE
1202_2 (ver: 200, 201, 202, 203, 204) Voltage Input: Default: SENSOR_TYPE_VOLTAGE
1203_0 (ver: 100) Voltage Input: Default: SENSOR_TYPE_VOLTAGE
1203_0 (ver: 120, 121) Voltage Input: Default: SENSOR_TYPE_VOLTAGE
1203_1 (ver: 123, 124) Voltage Input: Default: SENSOR_TYPE_VOLTAGE
1203_2 (ver: 200, 201, 202, 203, 204) Voltage Input: Default: SENSOR_TYPE_VOLTAGE
ADP1000_0 (ver: 104, 105) Voltage Input: Default: SENSOR_TYPE_VOLTAGE
DAQ1000_0 (ver: 102, 103) Voltage Input: Default: SENSOR_TYPE_VOLTAGE
DAQ1000_0 (ver: 110, 111, 112, 114) Voltage Input: Default: SENSOR_TYPE_VOLTAGE
DAQ1400_0 (ver: 112) Voltage Input: Default: SENSOR_TYPE_VOLTAGE
DAQ1400_0 (ver: 120, 121) Voltage Input: Default: SENSOR_TYPE_VOLTAGE
DAQ1400_0 (ver: 130) Voltage Input: Default: SENSOR_TYPE_VOLTAGE
HUB0000_0 (ver: 117, 118, 119) Voltage Input: Default: SENSOR_TYPE_VOLTAGE
HUB0000_0 (ver: 121, 125, 126, 127) Voltage Input: Default: SENSOR_TYPE_VOLTAGE
HUB0000_0 (ver: 307) Voltage Input: Default: SENSOR_TYPE_VOLTAGE
HUB0000_1 (ver: 400, 401) Voltage Input: Default: SENSOR_TYPE_VOLTAGE
HUB0001_0 (ver: 111, 113, 114) Voltage Input: Default: SENSOR_TYPE_VOLTAGE
HUB0001_0 (ver: 115, 116) Voltage Input: Default: SENSOR_TYPE_VOLTAGE
HUB0002_0 (ver: 100, 101) Voltage Input: Default: SENSOR_TYPE_VOLTAGE
HUB0007_0 (ver: 101, 102) Voltage Input: Default: SENSOR_TYPE_VOLTAGE
HUB5000_0 (ver: 100) Voltage Input: Default: SENSOR_TYPE_VOLTAGE
HUB5000_0 (ver: 102, 104, 105, 106) Voltage Input: Default: SENSOR_TYPE_VOLTAGE
HUB5000_0 (ver: 107) Voltage Input: Default: SENSOR_TYPE_VOLTAGE
HUB5000_0 (ver: 203, 204, 205) Voltage Input: Default: SENSOR_TYPE_VOLTAGE
SBC3003_0 (ver: 101, 102) Voltage Input: Default: SENSOR_TYPE_VOLTAGE
SBC3003_0 (ver: 108, 109, 110) Voltage Input: Default: SENSOR_TYPE_VOLTAGE
SBC3003_0 (ver: 203, 204) Voltage Input: Default: SENSOR_TYPE_VOLTAGE |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
Device Out Same as Device In |
|
|
error out error out passes error or warning information out of a VI to be used by other VIs. |
|
|
status status is TRUE (X) if an error occurred or FALSE (checkmark) to indicate a warning or that no error occurred. Right-click the error out control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error. |
|
|
code code is the error or warning code. Right-click the error out control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error. |
|
|
source source describes the origin of the error or warning. Right-click the error out control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error. |